SOM-200-0003

Microphone Cable Stage 22 Highflex; 2 x 0,22 mm²; PVC Ø 6,40 mm; red

Technical Data: - Properties: Analog - Properties: OFC oxygen free copper - Application area: Mobile outdoor / indoor - Application area: Stage / live - Application area: Installation - Application: Microphone Cable - Colour: red - Colour detailed: red - Signal transmission: symmetrical - Jacket material: PVC - Jacket Ø: 6,4 mm - Number of Channels (audio): 1 - Inner conductor (audio): 2 - Inner conductor (audio): 0,22 mm² - Inner conductor Ø (audio): 0,53 mm - AWG (audio): 24 - Shielding: Copper spiral shielding with 0.10 mm indiv. strands - Copper strands (audio): 28 - Copper strand Ø (audio): 0,10 mm - Weight per 1 m: 44 g - Fire load per m: 0,22 kWh - Style variant: round - Shielding factor: 99 % - Packing: 100 m spool - Packing: 500 m spool - Temperature min.: -20 °C - Temperature max.: 70 °C - Width: 6,4 mm - Height: 6,4 mm - Capac. cond./cond. per 1 m (audio): 68 pF - Capac. cond./shield. per 1 m (audio): 130 pF - Impedance: 100 Ω - Insulation resist. per 1 km: 1 GΩ - Insulation resist. per 1 km (audio): 1 GΩ - Conductor resistance per 1 km: 87 Ω - Shield. resistance per 1 km: 30 Ω

SOM-200-0002

Microphone Cable Stage 22 Highflex; 2 x 0,22 mm²; PVC Ø 6,40 mm; blue

Technical Data: - Properties: Analog - Properties: OFC oxygen free copper - Application area: Stage / live - Application area: Installation - Application area: Mobile outdoor / indoor - Application: Microphone Cable - Colour: blue - Colour detailed: blue - Signal transmission: symmetrical - Jacket material: PVC - Jacket Ø: 6,4 mm - Number of Channels (audio): 1 - Inner conductor (audio): 2 - Inner conductor (audio): 0,22 mm² - Inner conductor Ø (audio): 0,53 mm - AWG (audio): 24 - Shielding: Copper spiral shielding with 0.10 mm indiv. strands - Copper strands (audio): 28 - Copper strand Ø (audio): 0,10 mm - Weight per 1 m: 44 g - Fire load per m: 0,22 kWh - Style variant: round - Shielding factor: 99 % - Packing: 100 m spool - Packing: 500 m spool - Temperature min.: -20 °C - Temperature max.: 70 °C - Width: 6,4 mm - Height: 6,4 mm - Capac. cond./cond. per 1 m (audio): 68 pF - Capac. cond./shield. per 1 m (audio): 130 pF - Impedance: 100 Ω - Insulation resist. per 1 km: 1 GΩ - Insulation resist. per 1 km (audio): 1 GΩ - Conductor resistance per 1 km: 87 Ω - Shield. resistance per 1 km: 30 Ω

PRM-NTCCAT7ORANGE

NTC installation cable S/FTP CAT7 PiMF LSOH

SYN-MICROSTAGE

AUDIO MICROPHONE

SYNTAX AUDIO MICROPHONE. The featuring of this cable provides excellent flexibility and anti-knotting properties. The two insulated twisted conductors and drain wire are shielded with a high density copper wrap for the highest screening performance. This particular construction featuring the drain wire also improves the mechanical strength of the cable. The conductors are made of tinned OFC and insulated with a high thermal resistance XLPE sheath to avoid warping or shrinkage when soldering.
The special PVC compound of the outer jacket improves flexibility, abrasion resistance and water repellence as well as making the cable suitable for subflooring and anti-knotting. The jacket is flame retardant and allows the use of the cable even with very low temperatures.

PWC-Liyy05G1.5

Grey pvc cable Liyy-5x1,5

Cables designated as LiYY are unscreened flame-retardant multicore PVC cables for indoor signal and data transmission in indoor industrial applications such as computer systems, measuring equipment and process control devices in offices, laboratories and production lines under low mechanical and tensile stress. This range is particularly well suited to applications requiring a cable with a small overall diameter.

PWC-3G1.5-CCA

Flexible Power Cable H-07 3G1,5mm²/m - Outside diameter: 11,9mm

Locations where a low level of emission of smoke and corrosive gases are

required in case of fire or burning; use in industrial and agricultural

workshops, building sites, for heavy duty applications and supplying

industrial and agricultural machines and appliances where cables are

subject to medium mechanical stresses (e.g. heating plates, inspection

lamps, electric tools such as drills, circular saws, and domestic electric tools)

use in dry, humid or moist rooms; fixed installations e.g. on rough-cast in

temporary buildings and huts for accommodation purposes .Supply of

electricity and communications in buildings and other civil engineering

works with the objective of limiting the generation and spread of fire and

smoke.In addition the cables are especially suitable for use as connection to

machine tools


Filter by: